Customization: | Available |
---|---|
Display Type: | Site Display |
Connection Type: | Flange Type |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Characteristic
|
value
|
Description |
Certification |
S
|
FM IS Cl.I,II,III Div.1 Gr.A-G, NI Cl.I Div.2 Gr.A-D, AEx ia, zone 0,1,2,20,21,22 |
Output
|
1
|
"Recommended" 4-20mA HART; Internal + LCD |
Electrical connections: |
U
|
Hossman Fitting ISO4400 M16, IP65 NEMA Type 4X Encl. |
Overload: Overvoltage limit value |
1H
|
1bar/100kPa/15psi gauge pressure, overpressure limit: 10bar/1MPA/150psi |
Calibration, unit: |
B
|
Sensor range, mbar/bar |
Process connection: |
WBJ
|
Thread ISO228 G1/2 EN837, 316L |
Sealing ring: |
A
|
FKM |
-25 to +80 °C
|
± 0.20% of reading plus zero stability
|
|
± 0.1%
|
0.5%
|
|
Hastelloy C22
|
Platinum
|
|
DC 10-30V | DC 10-30V |