Model NO.
ATV610D45N4Z
Principle of Work
Vector Control Transducer
Switch Mode
PWM Control
Main Circuit Type
Current
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-AC Variable-Frequency Drive
Nature of DC Power
Current Variable-Frequency Drive
Function
Constant Torque Universal Type
Brand
Shme
Rated Switching Frequency
2.5 kHz
Switching Frequency
1... 8 kHz Adjustable
Brake to Stop
DC Injection
Analog Quantity Input Quantity
3
Discrete Quantity Input Quantity
6
Analog Quantity Output Quantity
2
Number of Relay Outputs
3
Communication Port Protocol
Modbus Serial
Cooling Mode
Forced Ventilation
Phase Number
3-Phase
Expected Line Isc
50 Ka
Power Supply Frequency
50...60 Hz +/-5 %
Transport Package
Carton
Specification
200*200*200
Trademark
SHME
Origin
China
HS Code
8537209000
Production Capacity
10000set/Year

Product Description



ATV610 Variable Speed Drives


3 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV610
3 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV610
3 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV610
Presentation:

The Easy  Altivar 310 drive is a frequency inverter for three-phase 380…460 V asynchronous motors rated from 0.37 kW/0.5 HP to 22 kW/30 HP. 
The compact size of this drive, its robust design, its ease of installation, based on the principle of Plug & Play, its integrated functions and macro configuration make it particularly suitable for applications involving industrial machines and certain consumer machines.
By taking account of the constraints governing installation and use at the product design stage, we have been able to offer a reliable, cost-effective solution to manufacturers of compact machines (OEMs). 
The Easy Altivar 310 has been developed with no compromise on quality and strong robustness in any situation even in harsh environment.
3 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV610
Applications:
The Easy Altivar 310 drive incorporates functions that are suitable for the most common applications, including:
1. Textile machine
2. Machine tools
3. Wood making machine
4. Material handling
5. Packaging and printing machines
6. Ceramic machine
7. Pump and fan
8. HVAC

3 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV610
3 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV610
Analog input AI1:
1 software-configurable voltage or current analog input:
a. Voltage analog input: 0...5 V c (internal power supply only) or 0...10 V c , impedance 30 kΩ
b.  Analog current input: X-Y mA by programming X and Y from 0-20 mA, Impedance 250 W
Sampling time: < 20 ms
Resolution: 10 bits
Accuracy: ± 1% at 25 °C/77 °F
Linearity: ± 0.3% of the maximum scale value
Factory setting: Input configured as voltage type.

3 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV610
Analog output AO1
1 software-configurable voltage or current analog output:
§ Analog voltage output: 0…10 V c , minimum load impedance 470Ω
§ Analog current output: 0-20 mA, maximum load impedance 800Ω
Sampling time: < 10 ms
Resolution: 8 bits
Accuracy: ± 1% at 25 °C/77 °F

3 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV610
Drives
Three-phase supply voltage: 380…460 V 50/60 Hz
Motor Line supply Easy Altivar 310
Power indicated on rating plate (1) Max. lin 
current (2)


 
Apparent
power
 
Maximum continuous output current (In) (1) Maximum transient current for 60 s Dissipated power at maximum output current(ln)(1) Reference (6) Weight (3)
HD: Heavy duty (4    
ND: Normal duty (5)    
      380 V 460V 460V 380V        
  kW HP A A KVA A A W   Kg/lb
HD 0.37 0.5 2.1 1.8 1.4 1.5 2.3 22.7 ATV310H037N4* 0.800/1.760
HD 0.75 1 3.5 3.1 2.5 2.3 3.5 34.1 ATV310H075N4* 0.800/1.760
HD 1.5 2 6.5 5.4 4.3 4.1 6.2 60.4 ATV310HU15N4* 1.100/2.430
HD 2.2 3 8.8 7.2 5.7 5.5 8.3 75.5 ATV310HU22N4* 1.100/2.430
HD 3 4 11.1 9.2 7.3 7.1 10.7 90.8 ATV310HU30N4* 1.800/3.970
ND 4 5 14.2 11.6 9.3 8.9 9.8 120.4
HD 4 5 13.7 11.4 9.1 9.5 14.3 115.1 ATV310HU40N4* 1.800/3.970
ND 5.5 7.5 18 14.9 15.1 12.1 13.3 158.3
HD 5.5 7.5 21.3 14.3 11.4 12.6 18.9 162.4 ATV310HU55N4* 1.800/3.970
ND 7.5 10 23 19 15.1 16 17.6 201.9
HD 7.5 10 26.6 22.4 17.8 17 25.5 241.2 ATV310HU75N4* 3.700/8.160
ND 11 15 29.5 24.8 19.4 22.8 25.1 317.8
HD 11 15 36.1 30.4 24.2 24 36 337.1 ATV310HD11N4* 3.700/8.160
ND 15 20 38.6 32.5 25.4 30 33 407
HD 15 20 46.5 38.5 30.7 33 49.5 416 ATV310HD15N4* 6.300/13.900
ND 18.5 25 46.5 38.8 31.2 36 39.6 451.7
HD 18.5 25 55.3 45.8 36.5 39 58.5 515.9 ATV310HD18N4* 6.300/13.900
ND 22 30 54.1 45.1 35.7 43 47.3 539.4
HD 22 30 64.2 53.2 46.2 46 69 568.8 ATV310HD22N4* 8.500/18.700
ND 30 40 71.2 59.2 47 60 66 735.6
HD 15 20 46.5 38.5 30.7 33 49.5 424.4 ATV310HD15N4*F 6.700/14.800
ND 18.5 25 46.5 38.8 31.2 36 39.6 460.2
HD 18.5 25 55.3 45.8 36.5 39 58.5 527.8 ATV310HD18N4*F 6.700/14.800
ND 22 30 54.1 45.1 35.7 43 47.3 55.09
HD 22 30 64.2 53.2 46.2 46 69 593.5 ATV310HD22N4*F 9.700/21.400
ND 30 40 71.2 59.2 47 60 66 765.9

3 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV610
(1)     These values are given for a nominal switching frequency of 4 kHz, for use in continuous operation. 
If operation above 4 kHz needs to be continuous, the nominal drive current should be derated by 10% for 8 kHz and 20% for 12 kHz.
The switching frequency can be set between 2 and 12 kHz for all ratings. 
Above 4 kHz, the drive will reduce the switching frequency automatically in the event of an excessive temperature rise. See the derating curves in the User Manual, available on our  local website.
(2)     Typical value for the indicated motor power and for the maximum prospective line Isc.
 •     ≤ 4kW, network short circuit current Isc ≤ 5kA
 •     > 4kW, network short circuit current Isc : ≤ 22kA for Heavy duty, ≤ 5kA for Normal duty 
(3)     Weight of product without packaging.
(4)     Values given for applications requiring significant overload (up to 150% for 60 s).
(5)     Values given for applications requiring slight overload (up to 110% for 60 s).
(6)     Easy Altivar ATV310pppN4pF drives with integrated EMC filter category C3 with 25 m/82 ft shielded motor cable.
3 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV610

An optimized offer
Environment
The entire range conforms to international standards IEC/EN 61800-5-1 and  
IEC/EN 61800-3 and has been developed to meet the requirements of directives regarding the protection of the environment (RoHS, WEEE).
Owing to its innovated air flow design and to its thicker coating which avoids polluting PCB, the range can be used in the harshest environments. It can withstand a 55 °C/131 °F ambiant air temperature around the device without derating (1).
Its degree of protection is IP 20 (IP4X on top with cover).


Adaptability and performances:
The Easy Altivar 310 has been designed with an increased adaptability to different motors and various tough loads.
One of its main quality is its torque capacity for starting and braking:
b Braking capacity:
v  over 80 % of the rated motor torque without braking resistor
v 150 % of the rated motor torque with braking resistor (see page 8)
b Torque capacity
v starting torque 150 % at 3 Hz
v over torque : 170 to 200 %, depending on model (2).
3 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV610
3 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV610

Easy to integrate in system:
The Easy Altivar 310 drive integrates as standard the Modbus communication protocol, which can be accessed via the RJ45 connector located on the underside of the drive 1 with a 2-wire RS 485 physical interface. To communicate on the network, the Easy Altivar 310 speed drive uses the Modbus RTU transmission mode. For more information on the complementary characteristics of the Modbus port 
(transmission speed, address, messaging...), please consult our local website. Logic input can be configured as source or sink by software, compatible with many PLCs.

3 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV610
Easy to install:
The Easy Altivar 310 drives can easily and quickly be installed as:
§ they are easy and quick to wire due to their Plug & Play concept
§ they can be identified on the front panel.
§ they can be mounted side by side to save cabinet space.
§ power terminal and connection labels are easily identified and differenciated b a connection guideline is shown inside the front door.

3 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV610
3 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV610
3 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV6103 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV6103 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV6103 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV6103 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV6103 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV6103 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV6103 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV6103 Phases, 45kw/60HP, VFD, Iverter, ATV610d45n4z, ATV610

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now